ATV12H037M2
SPECIFICATIONS:
Range of product |
Altivar 12 |
Product or component type |
Variable speed drive |
Product specific application |
Simple machine |
Mounting mode |
Cabinet mount |
Communication port protocol |
Modbus |
Supply frequency |
50/60 Hz +/- 5 % |
[Us] rated supply voltage |
200...240 V - 15...10 % |
Nominal output current |
2.4 A |
Motor power hp |
0.55 hp |
Motor power kW |
0.37 kW |
Motor power hp |
0.55 hp |
EMC filter |
Integrated |
IP degree of protection |
IP20 |
Discrete input number |
4 |
Discrete output number |
2 |
Analogue input number |
1 |
Analogue output number |
1 |
Relay output number |
1 |
Physical interface |
2-wire RS 485 |
Connector type |
1 RJ45 |
Continuous output current |
2.4 A at 4 kHz |
Method of access |
Server Modbus serial |
Speed drive output frequency |
0.5…400 Hz |
Speed range |
1…20 |
Sampling duration |
20 ms, tolerance +/- 1 ms for logic input 10 ms for analogue input |
Linearity error |
+/- 0.3 % of maximum value for analogue input |
Frequency resolution |
Analog input: converter A/D, 10 bits Display unit: 0.1 Hz |
Time constant |
20 ms +/- 1 ms for reference change |
Transmission rate |
9.6 kbit/s 19.2 kbit/s 38.4 kbit/s |
Transmission frame |
RTU |
Number of addresses |
1…247 |
Data format |
8 bits, configurable odd, even or no parity |
Communication service |
Read holding registers (03) 29 words Write single register (06) 29 words Write multiple registers (16) 27 words Read/write multiple registers (23) 4/4 words Read device identification (43) |
type of polarization |
No impedance |
4 quadrant operation possible |
False |
Asynchronous motor control profile |
Sensorless flux vector control Voltage/frequency ratio (V/f) Quadratic voltage/frequency ratio |
Maximum output frequency |
4 kHz |
Transient overtorque |
150…170 % of nominal motor torque depending on drive rating and type of motor |
Acceleration and deceleration ramps |
Linear from 0 to 999.9 s S U |
Motor slip compensation |
Adjustable Preset in factory |
Switching frequency |
2...16 kHz adjustable 4...16 kHz with derating factor |
Nominal switching frequency |
4 kHz |
Braking to standstill |
By DC injection |
Brake chopper integrated |
False |
Line current |
5.9 A at 100 V (heavy duty) 4.9 A at 120 V (heavy duty) |
Maximum input current |
4.9 A |
Maximum output voltage |
240 V |
Apparent power |
1.2 kVA at 240 V (heavy duty) |
Maximum transient current |
3.6 A during 60 s (heavy duty) 4.0 A during 2 s (heavy duty) |
Network frequency |
50...60 Hz |
Relative symmetric network frequency tolerance |
5 % |
Prospective line Isc |
1 kA |
Base load current at high overload |
2.4 A |
Power dissipation in W |
Natural: 27.0 W |
With safety function Safely Limited Speed (SLS) |
False |
With safety function Safe brake management (SBC/SBT) |
False |
With safety function Safe Operating Stop (SOS) |
False |
With safety function Safe Position (SP) |
False |
With safety function Safe programmable logic |
False |
With safety function Safe Speed Monitor (SSM) |
False |
With safety function Safe Stop 1 (SS1) |
False |
With sft fct Safe Stop 2 (SS2) |
False |
With safety function Safe torque off (STO) |
False |
With safety function Safely Limited Position (SLP) |
False |
With safety function Safe Direction (SDI) |
False |
Protection type |
Line supply overvoltage Line supply undervoltage Overcurrent between output phases and earth Overheating protection Short-circuit between motor phases Against input phase loss in three-phase Thermal motor protection via the drive by continuous calculation of I²t |
Tightening torque |
0.8 N.m |
Insulation |
Electrical between power and control |
Quantity per set |
Set of 1 |
Width |
72 mm |
Height |
143 mm |
Depth |
121.2 mm |
Net weight |
0.7 kg |
Operating altitude |
> 1000...2000 m with current derating 1 % per 100 m <= 1000 m without derating |
operating position |
Vertical +/- 10 degree |
Product certifications |
NOM CSA C-Tick UL GOST RCM KC |
Marking |
CE |
Standards |
UL 508C UL 618000-5-1 EN/IEC 61800-5-1 EN/IEC 61800-3 |
Assembly style |
With heat sink |
Electromagnetic compatibility |
Electrical fast transient/burst immunity test level 4 conforming to EN/IEC 61000-4-4 Electrostatic discharge immunity test level 3 conforming to EN/IEC 61000-4-2 Immunity to conducted disturbances level 3 conforming to EN/IEC 61000-4-6 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to EN/IEC 61000-4-3 Surge immunity test level 3 conforming to EN/IEC 61000-4-5 Voltage dips and interruptions immunity test conforming to EN/IEC 61000-4-11 |
Environmental class (during operation) |
Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3 |
Maximum acceleration under shock impact (during operation) |
150 m/s² at 11 ms |
Maximum acceleration under vibrational stress (during operation) |
10 m/s² at 13...200 Hz |
Maximum deflection under vibratory load (during operation) |
1.5 mm at 2...13 Hz |
Overvoltage category |
Class III |
Regulation loop |
Adjustable PID regulator |
Electromagnetic emission |
Radiated emissions environment 1 category C2 conforming to EN/IEC 61800-3 2...16 kHz shielded motor cable Conducted emissions with integrated EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <5 m Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 2...12 kHz shielded motor cable <5 m Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 2, 4 and 16 kHz shielded motor cable <10 m Conducted emissions with additional EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 4...12 kHz shielded motor cable <20 m Conducted emissions with additional EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 4...12 kHz shielded motor cable <50 m Conducted emissions with additional EMC filter environment 2 category C3 conforming to EN/IEC 61800-3 4...12 kHz shielded motor cable <50 m |
Vibration resistance |
1 gn (f = 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm peak to peak (f = 3…13 Hz) - drive unmounted on symmetrical DIN rail - conforming to EN/IEC 60068-2-6 |
Shock resistance |
15 gn conforming to EN/IEC 60068-2-27 for 11 ms |
Relative humidity |
5…95 % without condensation conforming to IEC 60068-2-3 5…95 % without dripping water conforming to IEC 60068-2-3 |
noise level |
0 dB |
Pollution degree |
2 |
Ambient air transport temperature |
-25…70 °C |
Ambient air temperature for operation |
-10…40 °C without derating 40…60 °C with current derating 2.2 % per °C |
Ambient air temperature for storage |
-25…70 °C |
Unit Type of Package 1 |
PCE |
Number of Units in Package 1 |
1 |
Package 1 Height |
12.600 cm |
Package 1 Width |
20.000 cm |
Package 1 Length |
18.700 cm |
Package 1 Weight |
1.035 kg |
Unit Type of Package 2 |
P06 |
Number of Units in Package 2 |
45 |
Package 2 Height |
75.000 cm |
Package 2 Width |
60.000 cm |
Package 2 Length |
80.000 cm |
Package 2 Weight |
59.530 kg |
Warranty |
18 months |
Reviews