LC1F265P7
SPECIFICATIONS:
Range |
TeSys |
Range of product |
TeSys F |
Product or component type |
Contactor |
Device short name |
LC1F |
Contactor application |
Resistive load Motor control |
Utilisation category |
AC-4 AC-3 AC-1 |
Poles description |
3P |
[Ue] rated operational voltage |
<= 1000 V AC-1 <= 690 V AC-3 <= 690 V AC-4 <= 460 V DC |
[Uc] control circuit voltage |
230 V AC 40...400 Hz |
[Ie] rated operational current |
350 A (at <40 °C) at <= 440 V AC AC-1 265 A (at <55 °C) at <= 440 V AC AC-3 |
[Uimp] rated impulse withstand voltage |
8 kV |
[Ith] conventional free air thermal current |
350 A (at 40 °C) |
Rated breaking capacity |
2120 A conforming to IEC 60947-4-1 |
[Icw] rated short-time withstand current |
2200 A 40 °C - 10 s 1230 A 40 °C - 30 s 950 A 40 °C - 1 min 620 A 40 °C - 3 min 480 A 40 °C - 10 min |
Associated fuse rating |
315 A aM at <= 440 V 400 A gG at <= 440 V |
Average impedance |
0.3 mOhm - Ith 350 A 50 Hz |
[Ui] rated insulation voltage |
1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C |
Power dissipation per pole |
37 W AC-1 21 W AC-3 |
Overvoltage category |
III |
power pole contact composition |
3 NO |
Motor power kW |
132 kW at 380...400 V AC 50/60 Hz (AC-3) 140 kW at 415 V AC 50/60 Hz (AC-3) 140 kW at 440 V AC 50/60 Hz (AC-3) 160 kW at 500 V AC 50/60 Hz (AC-3) 160 kW at 660...690 V AC 50/60 Hz (AC-3) 147 kW at 1000 V AC 50/60 Hz (AC-3) 75 kW at 220...230 V AC 50/60 Hz (AC-3) 51 kW at 400 V AC 50/60 Hz (AC-4) |
Control circuit voltage limits |
Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.15...0.2 Uc 40...400 Hz (at 55 °C) |
Mechanical durability |
10 Mcycles |
Inrush power in VA |
650 VA, 40...400 Hz cos phi 0.9 (at 20 °C) |
Hold-in power consumption in VA |
10 VA, 40...400 Hz cos phi 0.9 (at 20 °C) |
Maximum operating rate |
2400 cyc/h 55 °C |
Operating time |
40...65 ms closing 100...170 ms opening |
Connections - terminals |
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: bar 2 cable(s) - busbar cross section: 32 x 4 mm Power circuit: lugs-ring terminals 1 cable(s) 240 mm² Power circuit: connector 1 cable(s) 240 mm² Power circuit: bolted connection |
Tightening torque |
Control circuit: 1.2 N.m Power circuit: 35 N.m |
Mounting support |
Plate |
Heat dissipation |
8 W |
motor power range |
55…100 kW at 200…240 V 3 phases 110…220 kW at 480…500 V 3 phases 110…220 kW at 380…440 V 3 phases |
Motor starter type |
Direct on-line contactor |
Contactor coil voltage |
230 V AC standard |
Standards |
EN 60947-4-1 IEC 60947-1 IEC 60947-4-1 EN 60947-1 JIS C8201-4-1 |
Product certifications |
BV CSA LROS (Lloyds register of shipping) ABS UL CB DNV RMRoS RINA UKCA |
Compatibility code |
LC1F |
Control circuit type |
AC at 40...400 Hz |
IP degree of protection |
IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106 |
Protective treatment |
TH |
Ambient air temperature for operation |
-5…55 °C |
Ambient air temperature for storage |
-60…80 °C |
Permissible ambient air temperature around the device |
-40…70 °C |
Height |
203 mm |
Width |
201.5 mm |
Depth |
213 mm |
Operating altitude |
3000 m without derating |
Net weight |
7.44 kg |
Unit Type of Package 1 |
PCE |
Number of Units in Package 1 |
1 |
Package 1 Height |
24.500 cm |
Package 1 Width |
24.500 cm |
Package 1 Length |
25.500 cm |
Package 1 Weight |
8.020 kg |
Unit Type of Package 2 |
P06 |
Number of Units in Package 2 |
12 |
Package 2 Height |
75.000 cm |
Package 2 Width |
80.000 cm |
Package 2 Length |
60.000 cm |
Package 2 Weight |
104.240 kg |
Warranty |
18 months |
Reviews
There are no reviews yet.